VI | FEATURES OF FIRE PROTECTION (NFPA 5000 TABLES 7.2.1.1, 7.3.2.1, 7.3.5 (a), (b), 7.3.5.5, 7.4.1) | HIGH-RISE APARTMENT |
A |
CONSTRUCTION |
COMPLYING WITH CHAPTER 7 & 8 OF NFPA 5000 |
REQUIRED |
1 |
CONSTRUCTION (NON-COMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS) |
TYPE I OR TYPE II |
EXTERIOR BEARING WALLS |
HOURLY RATINGS REQUIRED PER TYPE OF CONSTRUCTION BASED ON NFPA 5000 HEIGHT & AREA REQUIREMENTS |
FRAMING, COLUMNS, BEAMS, GIRDERS, TRUSSES |
FLOOR CONSTRUCTION |
B |
SUBDIVISION OF BUILDING SPACES |
COMPLYING WITH NFPA 101 & NFPA 5000 |
REQUIRED |
1 |
FIRE BARRIERS |
COMPLYING WITH NFPA 101 & NFPA 5000 |
REQUIRED |
2 |
SEPARATION FROM OTHER OCCUPANCIES |
AS PER NFPA 101 TABLE 6.1.14.4.1 (a), (b) |
REQUIRED |
3 |
CORRIDORS RATED SEPARATION |
COMPLYING WITH NFPA 101.30 &31 |
|
|
REQUIRED SEPARATION |
NOT SPRINKLERED |
1-HR FRR* |
SPRINKLERED |
0.5-HR FRR* |
|
DOORS |
OPENING ONTO EXIT ACCES CORRIDORS |
20-MIN FPR* |
4 |
SMOKE PARTITIONS |
COMPLYING WITH NFPA 101 & NFPA 5000 |
NOT REQUIRED |
5 |
SMOKE BARRIERS |
COMPLYING WITH NFPA 101 & NFPA 5000 |
NOT REQUIRED |
C |
VERTICAL OPENINGS PROTECTION |
PROTECTION COMPLYING WITH NFPA CODES |
REQUIRED |
1 |
COMMUNICATING SPACES |
COMPLYING WITH CHAPTER 8 NFPA 101 |
PERMITTED |
2 |
ATRIUMS |
COMPLYING WITH CHAPTER 8 NFPA 101 |
PERMITTED |
3 |
CONVENIENCE OPENINGS |
COMPLYING WITH CHAPTER 8 NFPA 101 |
PERMITTED |
4 |
SHAFTS |
COMPLYING WITH CHAPTER 8 NFPA 101 |
PERMITTED |
5 |
MEZZANINES |
COMPLYING WITH CHAPTER 8 NFPA 101 |
PERMITTED |
6 |
CONCEALED SPACES & DRAFTSTOPS |
COMPLYING WITH CHAPTER 8 NFPA 101 |
REQUIRED |
|
EXTERIOR & INTERIOR WALL & PARTITION |
FIRE STOPPED AT EACH LEVEL, TOP STORY CEILING LEVEL & AT THE LEVEL OF SUPPORT FOR ROOFS |
REQUIRED |
|
UNOCCUPIED ATTIC SPACES |
DRAFTSTOPS INTO AREAS NOT EXCEEDING 280 SQM |
REQUIRED |
|
CONCEALED SPACES (CEILINGS & FLOORS) |
DRAFTSTOPS INTO AREAS NOT EXCEEDING 93 SQM |
REQUIRED |
|
CONCEALED SPACES (FLOORS & ROOFS) |
DRAFTSTOPS INTO AREAS NOT EXCEEDING 280 SQM |
REQUIRED |