Site:
- maximum density = 500 person per hectare (page 25)
- provide fence for substation area (note: check to sir nando the location of substation if applicable)
- off-site laundry facilities?
- Garbage collection? (30-35 m. away from any building) consider also - alternative disposal arrangement
- multi-purpose space? 300 sq.m. approximate, divisible by movable partition, window 20% of floor area
- cover the basketball court (consider rotating the orientation)
Labor Accomodation Room: (QF standard)
- 1 WC minimum per 4 persons
- 1 shower per 4 persons (1m wide x 1.2m deep)
- Minimum ceiling height = 2.4m
- travel distance from sleeping room to toilet / bath = 10m maximum
- all windows, doors and ventilation openings shall have "insect screens"
- minimum 6 sqm floor area per person
- provide privacy curtain for each bed (stain resistant fabric)
- 0.5 cu.m. bulk storage
- 0.2 cu.m. clothing storage (2.0 m high)
- 1.0 m. long open shelf by bed
- 1 task light & electrical outlet per each bed
- 1 openable window per room. minimum area = 10% of total floor area
- 1 tack board per each bed 1.2 sq.m. minimum
Labor Accomodation Room: (Lusail and UAE standard)
- 1 WC minimum per 8 workers
- 1 shower per 10 workers
- 1 handwash basin per 10 workers
- 1 urinal per 20 men
Mess Hall:
- kitchen area 0.14 sq.m. per person
- dining area 0.33 sq.m. per person
- maximum 800 person each hall
- windows minimum 20% of total floor area
- handwashing facilities before entering
- serving area for each nationalities
- 8 person per seating
- kitchen requirement on page 34
- 1 WC and 1 wash basin per 25 persons
Communal space:
- kitchen and dining
- laundry centralized
- medical clinic
- management office
- mosque (we might need minimum 500 sq.m.)
- police