Level of Protection | Low Hazard Storage Occupancy | Ordinary Hazard Storage Occupancy | High Hazard Storage Occupancy |
---|---|---|---|
(m) | (m) | (m) | |
Dead-End Corridor |
|||
Protected throughout by an approved, supervised automatic sprinkler system in accordance with 9.7.1.1(1) | NL | 30 | Prohibited, except as permitted by 7.11.4 |
Not protected throughout by an approved, supervised automatic sprinkler system in accordance with 9.7.1.1(1) | NL | 15 | Prohibited, except as permitted by 7.11.4 |
Common Path of Travel |
|||
Protected throughout by an approved, supervised automatic sprinkler system in accordance with 9.7.1.1(1) | NL | 30 | Prohibited, except as permitted by 7.11.4 |
Not protected throughout by an approved, supervised automatic sprinkler system in accordance with 9.7.1.1(1) | NL | 15 | Prohibited, except as permitted by 7.11.4 |
NL = Not Limited