Table 7.4.1 Allowable Building Height and Area (Sprinklered only)

  TYPE I TYPE II TYPE III TYPE IV TYPE V
Construction Type 442 332 222 111 000 211 200 2HH 111 000
Maximum Building Height (m) UL

36

55 26 23 26 23

26

21 18
OCCUPANCY                    
Assembly >1000 UL UL 12 3 1 3 NP 3 3 NP
UL UL UL

1,440m²

790

1,301

NP 1,394 1,068 NP
Assembly >300 UL UL 12 4 2 4 1 4 4 1
UL UL UL 1,440 790 1,301

790

1,394 1,068 511
Assembly <300 UL UL 12 4 2 4 2 4 4 2
UL UL UL 1,440 790 1,301 790 1,394 1,068 511
Assembly, outdoor UL UL UL UL UL 4 3 4 3 2
UL UL UL UL UL UL UL UL UL UL
Business UL UL 12 6 5 6 5 6 4 3
UL UL UL

3,484

2,137 2,648 1,765 3,345 1,672 836
Board and care, large UL UL 12 3 2 2 1 2 2 1
UL UL 5,110 1,765

929

1,533 929 1,672 975 418
Board and care, small UL UL 12 5 5 5 5 5 4 3
UL UL UL 2,230 1,486 2,230 1,486 1,905 1,115 650
Day care UL UL 12 6 4 4 2 2 4 2
UL UL 5,621 2,462 1,208 2,183 1,208 2,369 1,719 836
Detention and Correctional UL UL 12 2 2 2 2 2 2 2
UL UL UL 1,394 929 975 697 1,115 697 465
Educational UL UL 12 4 3 4 3 4 2 2
UL UL UL 2,462 1,347 2,183 1,347 2,369 1,719 883
Health care UL UL 12 3 1 1 NP 1 1 NP
UL UL UL 1,394 1,022 1,115 NP 1,115 883 NP
Health care, ambulatory UL UL 12 6 5 6 5 6 4 3
UL UL UL 3,484 2,137 2,648 1,765 3,345 1,672 836
Industrial, ordinary hazard UL UL 12 5 3 4 3 5 3 2
UL UL UL 2,323 1,440 1,765 1,115 3,112 1,301 790
Industrial, low hazard UL UL 12 6 4 5 4 6 4 3
UL UL UL 3,484 2,137 2,648 1,672 4,692 1,951 1,208
Mercantile UL UL 12 5 5 5 5 5 4 2
UL UL UL 1,997 1,161 1,719 1,161 1,905 1,301 836
Residential UL UL 12 5 5 5 5 5 4 3
UL UL UL 2,230 1,486 2,230 1,486 1,905 1,115 650
Residential, 1 and 2 family UL UL 12 5 5 5 5 5 4 3
UL UL UL UL UL UL UL UL UL UL
Storage, ordinary hazard UL UL 12 5 4 4 4 5 4 2
UL UL 4,459 2,415

1,626

2,415 1,626 2,369 1,301 836
Storage, low hazard UL UL 12 6 5 5 5 6 5 3
UL UL 7,339 3,623 2,415 3,623 2,415 3,577 1,951 1,254