APARTMENT | HOTEL | DWELLINGS | DORMITORY | BUSINESS | MERCANTILE | EDUCATIONAL | HEALTH CARE | STORAGE | INDUSTRIAL | BUIDING REHABILITATIONS | TEMPORARY BUILDINGS |

RESIDENTIAL DEVELOPMENT, DWELLINGS & VILLAS


RESIDENTIAL DEVELOPMENT, DWELLINGS & VILLAS
III BUILDING AND SITE ACCESS FOR FIRE FIGHTING & RESCUE DWELLINGS AND VILLAS
A SITE ACCESS CLEAR WIDTH/CLEAR HEIGHT (SITE ENTRY) 4.0M / 4.5M
       
B BUILDING SETBACKS / FIRE SEPARATION DISTANCE FROM LOT BOUNDARY 1.5M
FIREBREAKS FROM EACH UNIT / STRUCTURES (TO THE PROPERTY LINE) 1.5M
OPENINGS WITHIN 1.50M FIRE BREAK NOT PERMITTED
       
C FIRE ENGINE HARDSTANDING 6.0M X 15.0M MIN. SIZE NOT REQUIRED
       
D FIRE ENGINE ACCESS ROADS 4.0M WIDE (24 TON LOAD CAPACITY) 18M FROM MAIN ENTRANCE OF ANY DWELLING UNIT
       
IV MEANS OF EGRESS  
A COMPONENTS OF MEANS OF EGRESS  
1 SWING TYPE DOORS MINIMUM CLEAR WIDTH

710MM

2 STAIRS WALL ENCLOSURES FRP NOT REQUIRED
3 STANDARD STAIRS MINIMUM CLEAR WIDTH 915MM
4 SPIRAL STAIRS COMPLYING WITH NFPA 101 PERMITTED
5 HALLWAY/CORRIDORS MIN. CLEAR WIDTH INTERNAL CORRIDORS 915MM
       
B NUMBER OF EXITS    
  SINGLE EXIT DOOR AS MAIN EXIT/S REQUIRED
SECONDARY MEANS OF ESCAPE REQUIRED
  2 EXITS EACH AREA & LEVEL/STOREYS NOT REQUIRED
  STAIR/S AS MAIN EXITS/S 2 STOREYS OR MORE REQUIRED
       
C CAPACITY OF MEANS OF EGRESS    
1 OCCUPANT LOAD FACTOR   NO REQUIREMENTS
       
D ARRANGEMENT OF EXITS    
1 TRAVEL DISTANCE   NOT REQUIRED
2 COMMON PATH OF LIMIT   NOT REQUIRED
3 DEAD-END CORRIDORS   NOT REQUIRED
4 EXIT DISCHARGE DIRECT EXIT DISCHARGE TO BUILDING EXTERNAL REQUIRED
5 BASEMENT REQUIREMENTS 2 NUMBERS OF EXIT REQUIRED
SLEEPING ROOMS / BEDROOMS NOT PERMITTED
6 SWIMMING POOL REQUIREMENTS LIFEBUOY / LIFEGUARD REQUIRED
FIRST AID KIT REQUIRED
       
E ILLUMINATION OF EXITS   NOT REQUIRED
       
F MARKINGS OF THE MEANS OF EGRESS   NOT REQUIRED
       
V BUILDING CONSTRUCTION    
A CONSTRUCTION COMPLYING WITH CHAPTER 7 & 8 OF NFPA 5000  
1

CONSTRUCTION

(NON-COMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS

TYPE-I OR TYPE-II EXTERIOR BEARING WALLS 1-HR FRR*
FRAMING, COLUMNS, BEAMS, GIRDERS, TRUSSES 1-HR FRR*
FLOOR CONSTRUCTION 1-HR FRR*
B COMPARTMENTATION (WALLS BETWEEN UNITS)   1-HR FRR*
       
VI FIRE PROTECTION    
A DETECTION ALARM AND COMMUNICATION SYSTEMS    
1 FIRE ALARM SYSTEM IN ALL AREAS INCLUDING BASEMENTS MANUAL (STAND ALONE) / SMOKE ALARMS (BATTERY OR WIRED REQUIRED
B EXTINGUISHING REQUIREMENTS    
1 PORTABLE FIRE EXTINGUISHERS   REQUIRED
2 FIRE BLANKETS IN KITCHEN/S REQUIRED
3 STANDPIPE SYSTEM   NOT REQUIRED
4 FIRE HOSE REEL 25MM DIAMETER HOSE NOT REQUIRED
5 SPRINKLER SYSTEM   NOT REQUIRED
C SMOKE CONTROL AND EMERGENCY VENTILATION   NOT REQUIRED
D EMERGENCY POWER SUPPLY SYSTEM   NOT REQUIRED
1 ENCLOSURES / FIRE BARRIERS 1-HR FRR* - FIRE RESISTANCE RATING NOT APPLICABLE
2 OPENING PROTECTIVE / FIRE DOORS 0.5 FPR** - FIRE PROTECTION RATING NOT APPLICABLE