VII | FIRE PROTECTION (FRR* FIRE RESISTANCE RATING / FPR** FIRE PROTECTION RATING) | MEDIUM-RISE HOTEL |
A |
DETECTION ALARM AND COMMUNICATION SYSTEMS |
|
|
1 |
FIRE ALARM SYSTEM |
COMPLYING WITH NFPA 72 |
REQUIRED |
|
CARBON MONOXIDE ALARMS AND DETECTION SYSTEM |
GUEST ROOM/SUITES WITH COMMUNICATING ATTACHED GARAGE |
REQUIRED |
GUEST ROOM/SUITES CONTAINING A PERMANENTLY INSTALLED FUEL-BURNING APPLIANCE |
REQUIRED |
IN GARAGE |
NOT REQUIRED |
GUEST ROOMS/SUITES WITH COMMUNICATING ATTACHED GARAGE THAT ARE CONSIDERED AS OPEN PARKING STRUCTURE |
NOT REQUIRED |
GUEST ROOMS/SUITES WITH COMMUNICATING ATTACHED GARAGE THAT ARE MECHANICALLY VENTILATED |
NOT REQUIRED |
B |
EXTINGUISHING REQUIREMENTS |
COMPLIANCE WITH INDIVIDUAL CODES & STANDARDS |
REQUIRED |
1 |
PROTABLE FIRE EXTINGUISHERS |
TYPE AND RATING IN ACCORDANCE WITH NFPA 10 |
REQUIRED |
2 |
FIRE BLANKETS |
IN KITCHEN OR PANTRY |
REQUIRED |
3 |
STANDPIPE SYSTEM |
BUILDING EXCEEDING 9M IN HABITABLE HEIGHT |
REQUIRED |
4 |
FIRE HOSE REELS |
25MM DIAMETER HOSE |
REQUIRED |
5 |
AUTOMATIC SPRINKLER SYSTEM |
THROUGHOUT PROTECTION |
REQUIRED |
WITH GUEST ROOMS OR GUEST SUITES HAVING A DOOR OPENING DIRECTLY OUTSIDE AT THE STREET LEVEL |
NOT APPLICABLE |
WITH GUEST ROOMS OR GUEST SUITES HAVING AN EXTERIOR ACCESS COMPLYING WITH CHAPTER 7 OF NFPA 101 |
NOT APPLICABLE |
PROVIDED IN LIEAU OF THE REQUIRED DRAFTSTOPS IN CONCEALED SPACES |
PERMITTED |
ONE BASEMENT LEVEL USED AS CARPARK ONLY (WITH FLOOR AREA EXCEEDING 1115 SQM) |
REQUIRED |
ONE BASEMENT LEVEL USED AS MIXED OCCUPANCY |
REQUIRED |
BUILDING HAS MORE THAN ONE BASEMENT LEVEL |
REQUIRED |
6 |
OTHER EXTINGUISHING EQUIPMENT |
COMPLIANCE FROM INDIVIDUAL NFPA CODES & STANDARDS |
NOT REQUIRED |