OCCUPANCY TYPE (new building) CODE REF. FURNITURE & MATTRESSES TESTS
AMBULATORY (Not Sprinklered) (20.7.5.2, 20.7.5.3) The Furnitures shall meet the criteria in 10.3.2.1 and 10.3.3. The Mattresses shall meet the criteria in 10.3.2.2 and 10.3.4.
AMBULATORY (Sprinklered) (20.7.5.2, 20.7.5.3) Exempted from requirement of 10.3.2
ASSEMBLY (Sprinklered and not sprinklered) (12.7.4.5) Furnitures and Mattresses are not required to meet criteria of 10.3.2 (cigarette ignition resistance)
BUSINESS (Sprinklered and Not Sprinklered) (12.7.4) Furnitures and Mattresses are not required to meet criteria of 10.3.2 (cigarette ignition resistance)
DAYCARE (Sprinklered and Not Sprinklered) (16.7.4.5) Exempted from requirement of 10.3.2
HEALTHCARE (Sprinklered) (18.7.4.4) Exempted from requirement of 10.3.2
EDUCATIONAL (Not Sprinklered) (14.7.4.4) Comply to requirement of 10.3.2.1 and 10.3.2.2
EDUCATIONAL (Sprinklered) (14.7.4.4) Exempted from requirement of 10.3.2
ONE & TWO FAMILY DWELLINGS (24.3.3.4) Exempted from requirement of 10.3.2
HOTELS AND DORMITORIES (Sprinklered and Not Sprinklered) (28.3.3.4.1) Exempted from requirement of 10.3.2
APARTMENTS (Sprinklered and Not Sprinklered) (30.3.3.4.1) Exempted from requirement of 10.3.2
MERCANTILE (Sprinklered and Not Sprinklered) (36.7.4.4) Exempted from requirement of 10.3.2
STORAGE (Sprinklered and Not Sprinklered) (42.9) Exempted from requirement of 10.3.2
INDUSTRIAL (Sprinklered and Not Sprinklered) (40.7) Exempted from requirement of 10.3.2
-