{"id":1784,"date":"2018-12-06T11:10:58","date_gmt":"2018-12-06T11:10:58","guid":{"rendered":"http:\/\/shared4.info\/buildingcodes\/?p=1784"},"modified":"2023-08-26T13:38:16","modified_gmt":"2023-08-26T13:38:16","slug":"fire-fighting-lobby-nfpa-5000-requirements","status":"publish","type":"post","link":"https:\/\/shared4.info\/buildingcodes\/fire-fighting-lobby-nfpa-5000-requirements\/","title":{"rendered":"Fire Fighting Lobby &#8211; NFPA 5000 requirements"},"content":{"rendered":"<div><script async=\"\" src=\"https:\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-1106918897076625\" crossorigin=\"anonymous\"><\/script><br \/>\n<!-- Display Ad Horizontal --><br \/>\n<ins class=\"adsbygoogle\" style=\"display:block\" data-ad-client=\"ca-pub-1106918897076625\" data-ad-slot=\"6198983087\" data-ad-format=\"auto\" data-full-width-responsive=\"true\"><\/ins><br \/>\n<script><br \/>\n     (adsbygoogle = window.adsbygoogle || []).push({});<br \/>\n<\/script><\/div>\n<div class=\"elgg-output blog-post\">\n<div>\n<p>Image below is an example of Fire Fighting Lobby;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/shared4.info\/journal\/wp-content\/uploads\/2018\/01\/fire-fighting-lobby.jpg\" alt=\"\" width=\"861\" height=\"417\"><\/p>\n<hr>\n<p>Reference from NFPA 5000;<\/p>\n<p><strong>54.12.1.1<\/strong>&nbsp; A minimum of one fire service access elevators shall be sized in accordance with 54.3.2.<\/p>\n<p><strong>54.12.2.2.1<\/strong>&nbsp; Each fire service access elevator lobby shall have direct access to an exit stair enclosure.<\/p>\n<p><strong>54.12.2.2.2<\/strong>&nbsp; The exit stair enclosure shall also have access to the floor without passing through the fire service access elevator lobby.<\/p>\n<p><strong>54.12.3&nbsp;<\/strong> Standpipe Hose Connection.&nbsp; Each building exit stair having direct access to the fire service access elevator lobby shall be provided with standpipe hose connection in accordance with Section 55.4.<\/p>\n<p><strong>54.3.2<\/strong>&nbsp; The elevator car shall be sized and arranged to accommodate a 610-mm x 2130-mm) ambulance stretcher with minimum (125-mm) radius corner in the horizontal open position.<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Fire Fighting Lobby &#8211; Example image and NFPA 5000 references<\/p>\n<div class=\"read-more\"><a href=\"https:\/\/shared4.info\/buildingcodes\/fire-fighting-lobby-nfpa-5000-requirements\/\">Read more &#8250;<\/a><\/div>\n<p><!-- end of .read-more --><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57,47],"tags":[200,199,198,58,201],"_links":{"self":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/1784"}],"collection":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/comments?post=1784"}],"version-history":[{"count":3,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/1784\/revisions"}],"predecessor-version":[{"id":2052,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/1784\/revisions\/2052"}],"wp:attachment":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/media?parent=1784"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/categories?post=1784"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/tags?post=1784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}