{"id":25,"date":"2012-08-10T10:49:21","date_gmt":"2012-08-10T10:49:21","guid":{"rendered":"http:\/\/shared4.info\/buildingcodes\/?p=25"},"modified":"2023-08-26T13:31:08","modified_gmt":"2023-08-26T13:31:08","slug":"corridor-walls","status":"publish","type":"post","link":"https:\/\/shared4.info\/buildingcodes\/corridor-walls\/","title":{"rendered":"Corridor Walls"},"content":{"rendered":"<blockquote><p>NFPA 101-7.1.3.1 &#8211; if corridor is used as &#8220;<a href=\"https:\/\/i.pinimg.com\/originals\/e2\/7a\/2c\/e27a2c4180b510cb0002d7bf5ec09b81.jpg\">Exit Access<\/a>&#8221; and will serve &gt;30 occupants, then it&#8217;s walls must be 1-hour fire rated. Though this shall not apply where otherwise requirements are provided in table below.<\/p><\/blockquote>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"1\">\n<tbody>\n<tr class=\"yellow\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>OCCUPANCY TYPE<br \/>\n(new building)<br \/>\n<\/strong><\/td>\n<td id=\"side-bar1\" style=\"text-align: left;\" align=\"left\" valign=\"middle\" width=\"20%\"><strong>CODE REF.<\/strong><\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>CORRIDOR WALL FIRE RATING REQUIREMENTS<\/strong><\/td>\n<\/tr>\n<tr>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>AMBULATORY<\/strong><br \/>\n(Not Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(20.3.6.1 and 38.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">1-hour,<br \/>\nNo Requirement if occupied by single tenant,<\/td>\n<\/tr>\n<tr class=\"blue\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>AMBULATORY<\/strong><br \/>\n(Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(20.3.6.1 and 38.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">No Requirement<\/td>\n<\/tr>\n<tr>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>ASSEMBLY<\/strong><br \/>\n(Not Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(12.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">1-hour if OL &gt; 30,<br \/>\nNo requirement if 50% of exit capacity is discharging to outside.<\/td>\n<\/tr>\n<tr class=\"blue\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>ASSEMBLY<\/strong><br \/>\n(either Sprinklered or with smoke detection system)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(12.3.6.2)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">No Requirement<\/td>\n<\/tr>\n<tr>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>BUSINESS<\/strong><br \/>\n(Not Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(38.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">1-hour,<br \/>\nNo Requirement if occupied by single tenant,<\/td>\n<\/tr>\n<tr class=\"blue\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>BUSINESS <\/strong><br \/>\n(Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(38.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">No Requirement<\/td>\n<\/tr>\n<tr class=\"gray\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>HEALTHCARE <\/strong><\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(18.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">Limit transfer of smoke<\/td>\n<\/tr>\n<tr>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>EDUCATIONAL<\/strong><br \/>\n(Not Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(14.3.6)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">1-hour,<\/td>\n<\/tr>\n<tr class=\"blue\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>EDUCATIONAL<\/strong><br \/>\n(Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(14.3.6)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">Wall to be smoke partition<\/td>\n<\/tr>\n<tr class=\"gray\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>ONE &amp; TWO FAMILY DWELLINGS<br \/>\n<\/strong><\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(-)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">No Requirement<\/td>\n<\/tr>\n<tr>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>HOTELS AND DORMITORIES<br \/>\n<\/strong>(Not Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(28.3.6)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">1-hour<\/td>\n<\/tr>\n<tr class=\"blue\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>HOTELS AND DORMITORIES<br \/>\n<\/strong>(Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(28.3.6)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">30-minutes<\/td>\n<\/tr>\n<tr>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>APARTMENTS<br \/>\n<\/strong>(Not Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(30.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">1-hour<\/td>\n<\/tr>\n<tr class=\"blue\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>APARTMENTS<br \/>\n<\/strong>(Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(30.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">30-minutes<\/td>\n<\/tr>\n<tr>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>MERCANTILE<br \/>\n<\/strong>(Not Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(36.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">1-hour,<br \/>\nNot Required if space is occupied by single tenant<\/td>\n<\/tr>\n<tr class=\"blue\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>MERCANTILE<br \/>\n<\/strong>(Sprinklered)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(36.3.6.1)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">No Requirement<\/td>\n<\/tr>\n<tr class=\"gray\">\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\"><strong>STORAGE<br \/>\n<\/strong><\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"20%\">(42.3.6)<\/td>\n<td id=\"side-bar1\" align=\"left\" valign=\"middle\" width=\"40%\">No Requirement, provision of 7.1.3.1 shall not apply<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"square-ads\">\n<script async=\"\" src=\"https:\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-1106918897076625\" crossorigin=\"anonymous\"><\/script><br \/>\n<!-- Display Ads Square --><br \/>\n<ins class=\"adsbygoogle\" style=\"display:block\" data-ad-client=\"ca-pub-1106918897076625\" data-ad-slot=\"4384743501\" data-ad-format=\"auto\" data-full-width-responsive=\"true\"><\/ins><br \/>\n<script><br \/>\n     (adsbygoogle = window.adsbygoogle || []).push({});<br \/>\n<\/script><\/div>\n<div><\/div>\n<p>Notes:<\/p>\n<ul>\n<li>Code Reference used is NFPA-101 2012 edition unless otherwise noted.<\/li>\n<li>These information is not complete and intended to be used as quick references only, always refer to NFPA or your local codes for complete information.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Explore the fire rating requirements for corridor walls based on different occupancy types and building codes. This comprehensive reference table outlines the necessary fire resistance for corridor walls in various scenarios, from ambulatory to healthcare facilities. Understand the occupancy-specific regulations and code references for effective fire safety planning. Please note that this information is meant for quick reference only; always refer to NFPA standards or local building codes for complete and accurate details.<\/p>\n<div class=\"read-more\"><a href=\"https:\/\/shared4.info\/buildingcodes\/corridor-walls\/\">Read more &#8250;<\/a><\/div>\n<p><!-- end of .read-more --><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[45,3],"tags":[84,188,186,187,29,93,185],"_links":{"self":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/25"}],"collection":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/comments?post=25"}],"version-history":[{"count":44,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/25\/revisions"}],"predecessor-version":[{"id":2045,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/25\/revisions\/2045"}],"wp:attachment":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/media?parent=25"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/categories?post=25"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/tags?post=25"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}