{"id":841,"date":"2013-08-30T21:01:26","date_gmt":"2013-08-30T21:01:26","guid":{"rendered":"http:\/\/shared4.info\/buildingcodes\/?p=841"},"modified":"2013-08-31T11:49:59","modified_gmt":"2013-08-31T11:49:59","slug":"external-access-to-site-and-building","status":"publish","type":"post","link":"https:\/\/shared4.info\/buildingcodes\/external-access-to-site-and-building\/","title":{"rendered":"FSS 4.1 &#8211; External Access To Site And Building"},"content":{"rendered":"<table width=\"100%\" border=\"1\" cellpadding=\"1px\">\n<tr>\n<td colspan=\"2\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"50\">Item<\/td>\n<td>Provision<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Access Road \/ Fire Engine Hardstanding<\/td>\n<\/tr>\n<tr>\n<td width=\"50\">1.0<\/td>\n<td>4m-width fire fighting appliance access\/access road to the building   shall be provided and the gradient shall not exceed 1: 8.3. The angle of   approach and departure for any means of access road shall not exceed 1m   drop in 20m. The access road shall able to sustain the stationary load   of a 24-ton fire appliance.<\/td>\n<\/tr>\n<tr>\n<td width=\"50\">2.0<\/td>\n<td>In addition to access road, fire engine hardstanding of 6m x 15m   (minimum), with longer side parallel to the fa\u00e7ade of the building shall   be provided. The hardstanding shall withstand the stationary load of a   45-ton fire appliance. Access opening shall be provided along the   external wall of building fronting the fire engine hardstanding to   provide access to the building for fire fighting and rescue operations.<\/td>\n<\/tr>\n<tr>\n<td width=\"50\">3.0<\/td>\n<td>Hardstanding is not required for residential building such as bungalow.   Semi-detach and terrace houses regardless of building height.<\/td>\n<\/tr>\n<tr>\n<td width=\"50\">&nbsp;<\/td>\n<td>For landed residential development with shared communal facilities,   there is need of fire fighting appliance access road. The maximum travel   distance from the fire engine pump appliance to every point on the   project plan area of any building shall be 60m.<\/td>\n<\/tr>\n<tr>\n<td>4.0<\/td>\n<td>For residential building exceed the habitable height of 10m, fire engine   hardstanding shall be within 18m of the breeching inlet. The breeching   inlets shall be located on the external wall above ground level nearest   to the vertical run of the riser stack.<\/td>\n<\/tr>\n<tr>\n<td>5.0<\/td>\n<td>For resident building not exceed the habitable height of 10m, no fire   engine hardstanding is required. However, access road shall be provided   within a travel distance of 60m of every point on the projected plan   area of the building.<\/td>\n<\/tr>\n<tr>\n<td>6.0<\/td>\n<td>For building for institution, office, shop and places of public resort   with habitable height not exceeding 10m, fire engine access road shall   be provide within a travel distance of 45m from every point on projected   plan area of any building.<\/td>\n<\/tr>\n<tr>\n<td>7.0<\/td>\n<td>Length of fire engine hardstanding shall be provided based on the gross   floor area (including toilets, stores, circulation areas, etc) of the   largest floor in the building for institution, office, shop and places   of public resort with habitable height exceeding 10m. Please refer to   attachment for required length which is in term of the building   perimeter length. Different building types have different requirements.<\/td>\n<\/tr>\n<tr>\n<td>8.0<\/td>\n<td>Factory (industrial) and\u00a0 storage (warehouse) shall be provided with   hardstanding regardless of habitable height. Length of fire engine   hardstanding shall be provided based on the gross cubic volume   (including toilets, stores, circulation areas, etc) of the largest floor   in the building<\/td>\n<\/tr>\n<tr>\n<td>9.0<\/td>\n<td>Every part of the fire engine hardstanding and\/or access road shall be   within an unobstructed distance of\u00a0 50m away from a fire hydrant<\/td>\n<\/tr>\n<tr>\n<td>10.0<\/td>\n<td>Fire engine hardstanding shall be positioned so that the nearer edge   shall not less than 2m or not more than 10m from the centre position of   the access opening, measured horizontally.<\/td>\n<\/tr>\n<tr>\n<td>11.0<\/td>\n<td>Fire engine hardstanding shall be laid on the level platform or if on an incline, the gradient shall not exceed 1:15.<\/td>\n<\/tr>\n<tr>\n<td>12.0<\/td>\n<td>Fire engine hardstanding and access roads shall have an unobstructed vertical clearance of not less than 4.5 m.<\/td>\n<\/tr>\n<tr>\n<td>13.0<\/td>\n<td>Public road can serve as fire engine hardstanding provided the location   of such public roads is in compliance wit the requirements of distance   from access opening.<\/td>\n<\/tr>\n<tr>\n<td>14.0<\/td>\n<td>Fire engine hardstanding and access road shall be kept clear of   obstructions and other parts of the building, plants, trees or other   fixtures shall not obstruct the path between the fire engine   hardstanding and access opening.<\/td>\n<\/tr>\n<tr>\n<td>15.0<\/td>\n<td>The inner radius of turning facility for the fire engine hardstanding and access road shall be minimum 7m.<\/td>\n<\/tr>\n<tr>\n<td>16.0<\/td>\n<td>Dead-end fire department access roads in excess of 46 m in length shall   be provided with approved provisions for the fire apparatus to turn   around.<\/td>\n<\/tr>\n<tr>\n<td>17.0<\/td>\n<td>All corners of fire engine hardstanding shall be marked.<\/td>\n<\/tr>\n<tr>\n<td>18.0<\/td>\n<td>Marking of corners shall be in contrasting colour to the ground surfaces or finishes.<\/td>\n<\/tr>\n<tr>\n<td>19.0<\/td>\n<td>Fire engine hardstanding provided on turfed area must be marked with   contrasting object (preferably reflective) that is visible at night. The   markings are to be at an interval not more than 2m apart and shall be   provided on both sides of the fire engine hardstanding<\/td>\n<\/tr>\n<tr>\n<td>20.0<\/td>\n<td>Side post displaying the wordings &lsquo;Fire Engine Access \u2013 Keep Clear&rsquo;   shall be provided at the entrance of the fire engine hardstanding. Size   of wordings shall not be less than 50mm.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Access Openings<\/td>\n<\/tr>\n<tr>\n<td>21.0<\/td>\n<td>Access opening shall be spaced not more than 20m apart measured along   the external wall from centre to centre of all access openings.<\/td>\n<\/tr>\n<tr>\n<td>22.0<\/td>\n<td>Access shall include unobstructed external wall openings, windows,   balcony doors, glazed wall panels or access panels. Windows, doors, wall   panels or access panels must be readily openable from the inside and   outside, unless fitted with breakable glazing. Inside and outside of   access openings shall be unobstructed at all times during the occupancy   of the building.<\/td>\n<\/tr>\n<tr>\n<td>23.0<\/td>\n<td>An external wall which face the fire engine hardstanding and is   windowless or a blank wall shall be provided with access opening at each   storey.<\/td>\n<\/tr>\n<tr>\n<td>24.0<\/td>\n<td>Access opening shall be note less than 850mm wide by 1000mm high with   sill height of not more than 1100mm and height not less than 1800mm   above the inside floor level.<\/td>\n<\/tr>\n<tr>\n<td>25.0<\/td>\n<td>Panels to access openings shall be posted with either a red or orange   triangle of equal sides (minimum 150mm on each side), which can be   upright or inverted, on the external side of the wall and with wordings   &ldquo;Fire Fighting Access \u2013 Do Not Obstruct&rdquo; of at least 25mm height on the   internal side.<\/td>\n<\/tr>\n<tr>\n<td>26.0<\/td>\n<td>Buildings and construction regardless of occupancy, having a habitable   height of 10m or less, shall be exempted from the requirement to\u00a0provide   access opening.<\/td>\n<\/tr>\n<tr>\n<td>&nbsp;<\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<\/table>\n<p>&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;<br \/>\nANNEX<br \/>\n&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;<\/p>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"676\"><b>Building Type \u2013 Institutional, Office, Shop and Place of Public Resort<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">Gross floor area of largest floor<\/td>\n<td valign=\"top\" width=\"338\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">Minimum<\/td>\n<td valign=\"top\" width=\"338\">1\/6 perimeter (min 15m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">2000m<sup>2<\/sup> to 4000m<sup>2<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00bc perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;4000m<sup>2<\/sup> to 8000m<sup>2<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00bd perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;8000m<sup>2<\/sup> to 16000m<sup>2<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00be perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;16000m<sup>2<\/sup><\/td>\n<td valign=\"top\" width=\"338\">Island site access<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"676\">Building protected throughout by automatic sprinkler system<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">Minimum<\/td>\n<td valign=\"top\" width=\"338\">1\/6 perimeter (min 15m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">4000m<sup>2<\/sup> to 8000m<sup>2<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00bc perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;8000m<sup>2<\/sup> to 16000m<sup>2<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00bd perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;16000m<sup>2<\/sup> to 32000m<sup>2<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00be perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;32000m<sup>2<\/sup><\/td>\n<td valign=\"top\" width=\"338\">Island site access<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\"><\/td>\n<td valign=\"top\" width=\"338\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"676\"><b>Building Type \u2013 Factory and Storage<\/b><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"676\">Gross cubicle extend of the building<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">Minimum<\/td>\n<td valign=\"top\" width=\"338\">1\/6 perimeter (min 15m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;28400m<sup>3<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00bc perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;56800m<sup>3<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00bd perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;85200m<sup>3<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00be perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;113600m<sup>3<\/sup><\/td>\n<td valign=\"top\" width=\"338\">Island site access<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"676\">Building protected throughout by automatic sprinkler system<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">Minimum<\/td>\n<td valign=\"top\" width=\"338\">1\/6 perimeter (min 15m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;56800m<sup>3<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00bc perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;113600m<sup>3<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00bd perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;170400m<sup>3<\/sup><\/td>\n<td valign=\"top\" width=\"338\">\u00be perimeter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"338\">&gt;227200m<sup>3<\/sup><\/td>\n<td valign=\"top\" width=\"338\">Island site access<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>(not yet finished..)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<p>Item<br \/>\nProvision<\/p>\n<p>Access Road \/ Fire Engine Hardstanding<\/p>\n<p>1.0<br \/>\n4m-width fire fighting appliance access\/access road to the building   shall be provided and the gradient shall not exceed 1: 8.3. The angle of   approach and departure for any means of access road shall not exceed 1m   drop in 20m.<span class=\"ellipsis\">&hellip;<\/span><\/p>\n<div class=\"read-more\"><a href=\"https:\/\/shared4.info\/buildingcodes\/external-access-to-site-and-building\/\">Read more &#8250;<\/a><\/div>\n<p><!-- end of .read-more --><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[40],"tags":[],"_links":{"self":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/841"}],"collection":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/comments?post=841"}],"version-history":[{"count":5,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/841\/revisions"}],"predecessor-version":[{"id":874,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/posts\/841\/revisions\/874"}],"wp:attachment":[{"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/media?parent=841"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/categories?post=841"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shared4.info\/buildingcodes\/wp-json\/wp\/v2\/tags?post=841"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}