VII |
FIRE PROTECTION (FRR* FIRE RESISTANCE RATING / FPR** FIRE PROTECTION RATING) |
TYPE-C MERCANTILE |
A |
DETECTION ALARM AND COMMUNICATION SYSTEMS |
|
|
1 |
FIRE ALARM SYSTEM |
BUILDING IS THREE (3) OR MORE STORIES IN HEIGHT |
REQUIRED |
OCCUPANCY IS SUBJECT TO 50 OR MORE OCCUPANTS ABOVE OR BELOW THE LEVEL OF EXIT DISCHARGE |
REQUIRED |
OCCUPANCY IS SUBJECT TO 300 OR MORE TOTAL OCCUPANTS |
REQUIRED |
B |
EXTINGUISHING REQUIREMENTS |
COMPLIANCE WITH INDIVIDUAL CODES & STANDARDS |
REQUIRED |
1 |
PROTABLE FIRE EXTINGUISHERS |
TYPE AND RATING IN ACCORDANCE WITH NFPA 10 |
REQUIRED |
2 |
FIRE BLANKETS |
IN KITCHEN OR PANTRY |
REQUIRED |
3 |
STANDPIPE SYSTEM |
BUILDING EXCEEDING 9M IN HABITABLE HEIGHT |
NOT REQUIRED |
4 |
FIRE HOSE REELS |
25MM DIAMETER HOSE |
NOT REQUIRED |
5 |
AUTOMATIC SPRINKLER SYSTEM |
>3 STOREYS OR 1115SQM GROSS AREA |
NOT APPLICABLE |
232 SQM BASEMENT USED FOR SALE & STORAGE |
REQUIRED |
MIXED OCCUPANCIES |
REQUIRED |
PROVIDED IN LIEAU OF THE REQUIRED DRAFTSTOPS IN CONCEALED SPACES |
NOT REQUIRED |
6 |
OTHER EXTINGUISHING EQUIPMENT |
COMPLIANCE FROM INDIVIDUAL NFPA CODES & STANDARDS |
NOT REQUIRED |