Table 12.1.6


 Table 12.1.6 Construction Type Limitations for Assembly Occupancy

Stories in Heightb

Construction Type

Sprinklereda

Stories Below

1

2

3

4

≥5

I (442)c, d, e

Yes

X

X

X

X

X

X

No

NP

X4

X4

X4

X4

X4

I (332)c, d, e

Yes

X

X

X

X

X

X

No

NP

X4

X4

X4

X4

X4

II (222)c, d, e

Yes

X

X

X

X

X

X

No

NP

X4

X4

X4

X4

X4

II (111)c, d, e

Yes

X1

X

X

X

X3

NP

No

NP

X4

X4

X4

NP

NP

II (000)

Yes

X2

X

X4

NP

NP

NP

No

NP

X4

NP

NP

NP

NP

III (211)d

Yes

X1

X

X

X

X3

NP

No

NP

X4

X4

X4

NP

NP

III (200)

Yes

X2

X3

X4

NP

NP

NP

No

NP

X4

NP

NP

NP

NP

IV (2HH)

Yes

X1

X

X

X

X3

NP

No

NP

X4

X4

X4

NP

NP

V (111)

Yes

X1

X

X

X

X3

NP

No

NP

X4

X4

X4

NP

NP

V (000)

Yes

X2

X3

X4

NP

NP

NP

No

NP

X4

NP

NP

NP

NP

X: Permitted for assembly of any occupant load.

X1: Permitted for assembly of any occupant load, but limited to one story below the level of exit discharge.

X2: Permitted for assembly limited to an occupant load of 1000 or less, and limited to one story below the level of exit discharge.

X3: Permitted for assembly limited to an occupant load of 1000 or less.

X4: Permitted for assembly limited to an occupant load of 300 or less.

NP: Not permitted.

aProtected by an approved, supervised automatic sprinkler system in accordance with Section 9.7 in the following locations:

(1) Throughout the story of the assembly occupancy

(2) Throughout all stories below the story of the assembly occupancy, including all stories below the level of exit discharge

(3) In the case of an assembly occupancy located below the level of exit discharge, throughout all stories intervening between the story of the assembly occupancy and the level of exit discharge, including the level of exit discharge

b See 4.6.3.

cWhere every part of the structural framework of roofs in Type I or Type II construction is 20 ft (6100 mm) or more above the floor immediately below, omission of all fire protection of the structural members is permitted, including protection of trusses, roof framing, decking, and portions of columns above 20 ft (6100 mm).

dIn open-air fixed seating facilities, including stadia, omission of fire protection of structural members exposed to the outside atmosphere is permitted where substantiated by an approved engineering analysis.

eWhere seating treads and risers serve as floors, such seating treads and risers are permitted to be of 1-hour fire resistance–rated construction. Structural members supporting seating treads and risers are required to conform to the requirements of Table 12.1.6. Joints between seating tread and riser units are permitted to be unrated, provided that such joints do not involve separation from areas containing high hazard contents and the facility is constructed and operated in accordance with 12.4.2.