Allowable Building Height – Business

Read more ›



Allowable Building Height – Residential

Read more ›



Limiting Size of Wired Glass Vision Panel

Read more ›

Tags:

LPG Tank

Discover the safe distance regulations for propane tanks and their connections. Learn about container separation distance requirements for various tank sizes. Ensure legal and secure propane tank placement based on NFPA guidelines.



Table 40.2.5

Level of Protection
General Industrial Occupancy
Special Purpose Industrial Occupancy
High Hazard Industrial Occupancy

Dead-End Corridor

Sprinklered
15-m
15-m
Prohibited except if permitted by 7.11.4

Not Sprinklered
15-m
15-m
Prohibited except if permitted by 7.11.4

Common Path of Travel

Sprinklered
30-m
30-m
Prohibited except if permitted by 7.11.4

Not Sprinklered
15-m
15-m
Prohibited except if permitted by 7.11.4

Travel Distance

Sprinklered
76-m
122-m
23-m

Not Sprinklered
61-m
91-m
Not Permitted

Read more ›



Table 8.3.4.2

check this link..

http://shared4.info/html/nfpa/101/table-8.3.4.2.html

Notes:

  • Code Reference used is NFPA-101 2012 edition unless otherwise noted.
  • These information is not complete and intended to be used as quick references only, always refer to NFPA or your local codes for complete information.

Read more ›



Table 16.1.6.1

16.1.6.1  Day-care occupancies, other than day-care homes, shall be limited to the building construction types specified in Table 16.1.6.1 based on the number of stories in height as defined in 4.6.3(See 8.2.1.)

Table 16.1.6.1  Construction Type Limitations for Day-Care Occupancy

Stories in Heightb

Construction Type

Sprinklereda

One Story Belowc

1

2

3–4

>4 but Not
High-Rise

High-Rise

I (442)

Yes

X

X

X

X

X

X

No

NP

X

X

X

NP

NP

I (332)

Yes

X

X

X

X

X

X

No

NP

X

X

X

NP

NP

II (222)

Yes

X

X

X

X

X

X

No

NP

X

X

X

NP

NP

II (111)

Yes

X

X

X

X

X

NP

No

NP

X

NP

NP

NP

NP

II (000)

Yes

X

X

X

X

NP

NP

No

NP

X

NP

NP

NP

NP

III (211)

Yes

X

X

X

X

NP

NP

No

NP

X

NP

NP

NP

NP

III (200)

Yes

NP

X

X

NP

NP

NP

No

NP

X

NP

NP

NP

NP

IV (2HH)

Yes

X

X

X

NP

NP

NP

No

NP

X

NP

NP

NP

NP

V (111)

Yes

X

X

X

X

NP

NP

No

NP

X

NP

NP

NP

NP

V (000)

Yes

NP

X

X

NP

NP

NP

No

NP

X

NP

NP

NP

NP

X: Permitted.

Read more ›



Table 18.1.6.1

Table 18.1.6.1  Construction Type Limitations for Health Care Occupancy

Construction Type
Sprinklered
Total Number of Stories of Building

1
2
3
≥4

I (442)
Yes
X
X
X
X

No
NP
NP
NP
NP

I (332)
Yes
X
X
X
X

No
NP
NP
NP
NP

II (222)
Yes
X
X
X
X

No
NP
NP
NP
NP

II (111)
Yes
X
X
X
NP

No
NP
NP
NP
NP

II (000)
Yes
X
NP
NP
NP

No
NP
NP
NP
NP

III (211)
Yes
X
NP
NP
NP

No
NP
NP
NP
NP

III (200)
Yes
NP
NP
NP
NP

No
NP
NP
NP
NP

IV (2HH)
Yes
X
NP
NP
NP

No
NP
NP
NP
NP

V (111)
Yes
X
NP
NP
NP

No
NP
NP
NP
NP

V (000)
Yes
NP
NP
NP
NP

No
NP
NP
NP
NP

X: Permitted.

Read more ›



Table 12.1.6

 Table 12.1.6 Construction Type Limitations for Assembly Occupancy

Stories in Heightb

Construction Type

Sprinklereda

Stories Below

1

2

3

4

≥5

I (442)c,

Read more ›