Table 16.1.6.1


16.1.6.1  Day-care occupancies, other than day-care homes, shall be limited to the building construction types specified in Table 16.1.6.1 based on the number of stories in height as defined in 4.6.3(See 8.2.1.)

Table 16.1.6.1  Construction Type Limitations for Day-Care Occupancy

Stories in Heightb

Construction Type

Sprinklereda

One Story Belowc

1

2

3–4

>4 but Not
High-Rise

High-Rise

I (442)

Yes

X

X

X

X

X

X

No

NP

X

X

X

NP

NP

I (332)

Yes

X

X

X

X

X

X

No

NP

X

X

X

NP

NP

II (222)

Yes

X

X

X

X

X

X

No

NP

X

X

X

NP

NP

II (111)

Yes

X

X

X

X

X

NP

No

NP

X

NP

NP

NP

NP

II (000)

Yes

X

X

X

X

NP

NP

No

NP

X

NP

NP

NP

NP

III (211)

Yes

X

X

X

X

NP

NP

No

NP

X

NP

NP

NP

NP

III (200)

Yes

NP

X

X

NP

NP

NP

No

NP

X

NP

NP

NP

NP

IV (2HH)

Yes

X

X

X

NP

NP

NP

No

NP

X

NP

NP

NP

NP

V (111)

Yes

X

X

X

X

NP

NP

No

NP

X

NP

NP

NP

NP

V (000)

Yes

NP

X

X

NP

NP

NP

No

NP

X

NP

NP

NP

NP

X: Permitted. NP: Not Permitted.

aSprinklered throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.

bSee 4.6.3.

cOne story below the level of exit discharge.

http://codesonline.nfpa.org/imagepop.php?id=2012_tab_NFPA-101_16.1.6.1