16.1.6.1 Day-care occupancies, other than day-care homes, shall be limited to the building construction types specified in Table 16.1.6.1 based on the number of stories in height as defined in 4.6.3. (See 8.2.1.)
|
Table 16.1.6.1 Construction Type Limitations for Day-Care Occupancy |
|||||||
|
Stories in Heightb |
|||||||
|
Construction Type |
Sprinklereda |
One Story Belowc |
1 |
2 |
3–4 |
>4 but Not |
High-Rise |
| I (442) |
Yes |
X |
X |
X |
X |
X |
X |
|
No |
NP |
X |
X |
X |
NP |
NP |
|
| I (332) |
Yes |
X |
X |
X |
X |
X |
X |
|
No |
NP |
X |
X |
X |
NP |
NP |
|
| II (222) |
Yes |
X |
X |
X |
X |
X |
X |
|
No |
NP |
X |
X |
X |
NP |
NP |
|
| II (111) |
Yes |
X |
X |
X |
X |
X |
NP |
|
No |
NP |
X |
NP |
NP |
NP |
NP |
|
| II (000) |
Yes |
X |
X |
X |
X |
NP |
NP |
|
No |
NP |
X |
NP |
NP |
NP |
NP |
|
| III (211) |
Yes |
X |
X |
X |
X |
NP |
NP |
|
No |
NP |
X |
NP |
NP |
NP |
NP |
|
| III (200) |
Yes |
NP |
X |
X |
NP |
NP |
NP |
|
No |
NP |
X |
NP |
NP |
NP |
NP |
|
| IV (2HH) |
Yes |
X |
X |
X |
NP |
NP |
NP |
|
No |
NP |
X |
NP |
NP |
NP |
NP |
|
| V (111) |
Yes |
X |
X |
X |
X |
NP |
NP |
|
No |
NP |
X |
NP |
NP |
NP |
NP |
|
| V (000) |
Yes |
NP |
X |
X |
NP |
NP |
NP |
|
No |
NP |
X |
NP |
NP |
NP |
NP |
|
X: Permitted. NP: Not Permitted.
aSprinklered throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.
bSee 4.6.3.
cOne story below the level of exit discharge.
http://codesonline.nfpa.org/imagepop.php?id=2012_tab_NFPA-101_16.1.6.1